Specialized Dynamic Analysis of Pipeline Pumping and Metering Station
Specialized Dynamic Analysis of Pipeline Pumping and Metering Station
Quebec, Canada
Problem Definition:
The client experienced excessive vibration of piping in one of their critical and large facilities during startup and shutdown.
EAMEC Scope:
- Review the piping system and field observations.
- Investigate the root cause of vibration.
- Provide mitigations to reduce or eliminate vibration.
- Develop a Construction Work Package for the field construction company to execute the changes.
- Provide construction support during the modifications.
Proposed Solution:
- Conduct dynamic analysis on the piping system.
- Install anti-vibration clamps at key locations.
- Review and reinforce pipe support structures to withstand dynamic forces.
Steps Taken:
- Reviewed pressure surge profiles and calculated unbalanced forces.
- Built a stress model for the piping and performed a time history analysis.
- Reviewed vibration modes and matched with field observations.
- Proposed anti-vibration pipe clamps and structural reinforcements.
Deliverables:
- Dynamic analysis report.
- Construction work package for modifications.
Outcomes and Benefits for the Client:
- Significant reduction or elimination of vibration.
- Safer system operation and prolonged service life.
- Prevention of high costs due to vibration-induced failures.